Questo sito utilizza cookies tecnici e di terze parti, per migliorare la tua esperienza e offrire servizi in linea con le tue preferenze. Chiudendo questo banner, scorrendo questa pagina o cliccando qualunque suo elemento acconsenti all'uso dei cookie. Se vuoi saperne di più o negare il consenso a tutti o ad alcuni cookie clicca sul pulsante 'Maggiori informazioni'.

Product certifications

main_certificazioni

Security doors burglar-proof certified

All Dierre doors hold the burglar proof certification following the ENV1627-1 European standard. Doors certified as airtight (class A) and/or watertight (class E).
Doors which have passed specific seal tests for the passage of air and/or water.

These tests are performed within official laboratories, obtaining the relative certificates foreseen by the European UNI EN 42 (air) and UNI EN 86 (water) standards.


PERFORMANCE OF SECURITY DOORS
PERFORMANCE REFERENCE STANDARDS VALUE
Break-in resistance ENV 1627-28-29-30 Classes 2, 3, 4, 5
Thermal transmittance EN 10077-1 EN 10077-2 EN 14351-1 Up to 0,9 W / m2 K
Noise reduction EN 717-1 EN 140-3 From 35 dB to 43 dB
Air permeability EN 1026 - EN 12207 Classes 2, 3, 4
Water tightness EN 1027 - EN 12208 Up to class 8A
Resistance to wind load EN 12210 - EN 12211 C 5
Resistance to fire (EI) EN 1634-1 EI2 30 - EI2 60
Resistance to fire (REI) UNI 9723 REI 30, REI 60, REI 90

PERFORMANCE OF SCREEN WINDOWS
PERFORMANCE REFERENCE STANDARDS VALUE
Break-in resistance ENV 1627-28-29-30 Class 3
Thermal transmittance EN 10077-1 - EN 10077-2 - EN 14351-1 1,4 W / m2 K
Noise reduction EN 717-1 EN 140-3 39 - 41 dB
Air permeability EN 1026 - EN 12207 Class 4
Water tightness EN 1027 - EN 12208 Class 7A
Resistance to wind load EN 12210 - EN 12211 C 5

PERFORMANCE OF GRILLES AND ANTHOS
PERFORMANCE REFERENCE STANDARDS VALUE
Break-in resistance ENV 1627-28-29-30 Class 3

PERFORMANCE OF IDRA DOORS
PERFORMANCE REFERENCE STANDARDS VALUE
Resistance to fire (EI) EN 1634-1 EI2 30 - 60 - 120
Resistance to fire (REI) UNI 9723 REI 60-120
Thermal transmittance EN 10077-1 - EN 10077-2 - EN 14351-1 1,8 - 2,0 W / m2 K
Noise reduction EN 717-1 - EN 140-3 Up to 35 dB
Air permeability EN 1026 - EN 12207 Up to Class 4
Resistance to wind load EN 12210 - EN 12211 Up to C4
Durability EN 12400 C5

PERFORMANCE OF VISUAL DOORS
PERFORMANCE REFERENCE STANDARDS VALUE
Resistance to fire (EI) EN 1634-1 EI2 60
Resistance to fire (REI) UNI 9723 REI 60-90-120
Noise reduction EN 717-1 - EN 140-3 Up to 35 dB

PERFORMANCE OF ROLLING MAIN DOORS
PERFORMANCE REFERENCE STANDARDS VALUE
Resistance to fire (EI) EN 1634-1 EI2 60-120
Resistance to fire (REI) UNI 9723 REI 60-90-120


(*) NOTE:
CLASSE 2 = Palace
CLASSE 3 = AT, Sentry, Elettra, D-Code e Hi-Fi